Items - Fenestrated Radial entry and multipurpose shield,Fenestrated Radial entry and multipurpose shield,Fenestrated Radial entry and multipurpose shield,Fenestrated Radial entry and multipurpose shield,Multipurpose shield Fenestrated Radial entry shield,Multipurpose shield Fenestrated Radial entry shield,Multipurpose shield Fenestrated Radial entry shield,Multipurpose shield Fenestrated Radial entry shield,Femoral entry angiography shield,Femoral entry angiography shield,Femoral entry angiography shield,Femoral entry angiography shield,EP subclavian shield,EP subclavian shield,EP subclavian shield,EP subclavian shield,No Brainer Head Cover for radiation protection,No Brainer Head Cover for radiation protection,No Brainer Head Cover for radiation protection,No Brainer Head Cover for radiation protection
Item Number | Item Title | Item Description | Item Quantity | Unit of Measure | Consignee ID | Delivery Period (In number of days) |
---|---|---|---|---|---|---|
1 | Fenestrated Radial entry and multipurpose shield | Single layer sterilized non vinyl non rubber nonleaded and light weight absorbable pad or shield for safety during interventional radial procedures quoted model should have BARC test certificate mmbp should not be greater than 0 point 135mm Mandatory Document need to be submitted that proff of core material must be free from environmental hazards clearance for non polluting disposal from government agency is required and it must be clearly mentioned in the IFU to be disposed of like a normal surgical item clinically proven and evidence supported be large number of patient studies proff of safety no backscattering to the patient during application drape size 406mm Into 365mm | 1000 | pieces | STORESSURGCONS.VMMC | 90 |
2 | Multipurpose shield Fenestrated Radial entry shield | Single layer sterilized non vinyl non rubber nonleaded and light weight absorbable pad or shield for safety during interventional radial procedures quoted model should have BARC test certificate mmbp should not be greater than 0 point 135mm Mandatory Document need to be submitted that proff of core material must be free from environmental hazards clearance for non polluting disposal from government agency is required and it must be clearly mentioned in the IFU to be disposed of like a normal surgical item clinically proven and evidence supported be large number of patient studies proff of safety no backscattering to the patient during application drape size 406mm Into 365mm | 1000 | pieces | STORESSURGCONS.VMMC | 180 |
3 | Femoral entry angiography shield | Single layer sterilized non vinyl non rubber nonleaded and light weight absorbable pad or shield for safety during interventional radial procedures quoted model should have BARC test certificate mmbp should not be greater than 0 point 135mm Mandatory Document need to be submitted that proff of core material must be free from environmental hazards clearance for non polluting disposal from government agency is required and it must be clearly mentioned in the IFU to be disposed of like a normal surgical item clinically proven and evidence supported be large number of patient studies proff of safety no backscattering to the patient during application size 406mm X 365mm | 500 | pieces | STORESSURGCONS.VMMC | 180 |
4 | EP subclavian shield | Single layer sterilized non vinyl non rubber nonleaded and light weight absorbable pad or shield for safety during interventional radial procedures quoted model should have BARC test certificate mmbp should not be greater than 0 point 135mm Mandatory Document need to be submitted that proff of core material must be free from environmental hazards clearance for non polluting disposal from government agency is required and it must be clearly mentioned in the IFU to be disposed of like a normal surgical item clinically proven and evidence supported be large number of patient studies proff of safety no backscattering to the patient during application drape size 406mm X 365 | 250 | pieces | STORESSURGCONS.VMMC | 180 |
5 | No Brainer Head Cover for radiation protection | Single layer sterilized non vinyl non rubber nonleaded and light weight absorbable pad or shield for safety during interventional radial procedures quoted model should have BARC test certificate mmbp should not be greater than 0 point 135mm Weight should not be more than 95grams size 559mmX76mm Mandatory Document need to be submitted that proff of core material must be free from environmental hazards and evedence of non polluting | 2500 | pieces | STORESSURGCONS.VMMC | 180 |