Items - VRF Outdoor Unit,VRF Hiwall indoor unit,wireless remote controllers,Y joints,Lifting shifting and commissioning,Suction Line,Discharge Line,Cables,Drain Pipes,Stands,Drain Pump,Dismantling
Item Number | Item Title | Item Description | Item Quantity | Unit of Measure | Consignee ID | Delivery Period (In number of days) |
---|---|---|---|---|---|---|
1 | VRF Outdoor Unit | Supply of VRF/VRV SYSTEM with only Cooling facility comprising of 100% DC inverter based scroll compressor Outdoor unit of capacity 12 HP connectable to multiple indoor units. | 1 | set | SBILHOGUW.BUY3 | 21 |
2 | VRF Hiwall indoor unit | Supply of VRF type hiwall 2.0 TR unit to be connected to the above VRF system. | 6 | set | SBILHOGUW.BUY3 | 21 |
3 | wireless remote controllers | Supply of wireless remote controllers | 6 | set | SBILHOGUW.BUY3 | 21 |
4 | Y joints | Supply and fixing of Refnet Y Joint for Indoor & Outdoor Units. | 6 | set | SBILHOGUW.BUY3 | 21 |
5 | Lifting shifting and commissioning | Lifting upto 5th floor level and Instalation of all the above mentioned as per item Number 1 and 2 VRF machine Out Door / Indoor Units without damagiging the Bank property. | 1 | Lot | SBILHOGUW.BUY3 | 21 |
6 | Suction Line | Supply Installation Testing and Commissioning of mirror finish inside /outside hard drawn copper refrigerant piping, including 19 mm class O armaflex nitrile thermal insulation suitable for VRV/VRF system including all fittings like bends elbows tees with all internal joint type fittings. | 35 | Mtr | SBILHOGUW.BUY3 | 21 |
7 | Discharge Line | Supply Installation Testing and Commissioning of mirror finish inside /outside hard drawn copper refrigerant piping, including 19 mm class O armaflex nitrile thermal insulation suitable for VRV/VRF system including all fittings like bends elbows tees with all internal joint type fittings. | 35 | Mtr | SBILHOGUW.BUY3 | 21 |
8 | Cables | Supply and laying termination and commissioning of 1.5 sqmm 2 core shielded communication cable between Indoor unit and outdoor unit and for centralized remote control laid in PVC conduit. | 40 | Mtr | SBILHOGUW.BUY3 | 21 |
9 | Drain Pipes | supply and fixing of 40 mm UPVC pipe with 9 mm insulation for drain | 40 | Mtr | SBILHOGUW.BUY3 | 21 |
10 | Stands | Supply and fixing of MS structure with catwalk and handrail approx size 4mtr x 2 mtr suitable for taking up the VRF AC ourdoor unit load and suitable for maintenance. The structure must be fixed on buiding wall. Placing of machine with rib rubber pad for VRF outdoor unit 12 HP. The unit is to placed by cutting window and reparing the same thereat. | 1 | Set | SBILHOGUW.BUY3 | 21 |
11 | Drain Pump | Supply and fixing of Aspen pump of 12LPH with 2 mtr head in each of the indoor unit and connecting the pump to the header line of UPVC drain pipe | 6 | Set | SBILHOGUW.BUY3 | 21 |
12 | Dismantling | Removing of existing Casette AC indoor units from ceiling and outdoor units from walls at 5th floor | 5 | Lumpsum | SBILHOGUW.BUY3 | 21 |