Items - Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed.,Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil complete all as specified and as directed.,Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed.,M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness,M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed.,M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable cross sectional area 300 sqmm 3.5 core.,All as per Item Sl No.

Tender Details
Costs
Documents
BOQ
Item NumberItem TitleItem DescriptionItem QuantityUnit of MeasureConsignee IDDelivery Period (In number of days)
1 Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth, getting out in Soft / Loose Soil, complete all as specified and as directed. 520 CUM con688.ia.wb@gembuyer.in 180
2 Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil complete all as specified and as directed. Returning, Filling in, including Spreading, Levelling, Watering and Well Ramming in Layers not exc. 250mm in Soft/Loose Soil, complete all as specified and as directed. 297 CUM con688.ia.wb@gembuyer.in 180
3 Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. Removing excavated Materials (Soils) not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil, complete all as specified and as directed. 223 CUM con688.ia.wb@gembuyer.in 180
4 M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness M and L Sand Cushioning dry in Trenches for protec-tion of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. (NOTE. For the purpose of Payment, Punned thick-ness of Sand Cushioning only shall be Measured and Paid ). 187 CUM con688.ia.wb@gembuyer.in 180
5 M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, complete all as specified and as directed. 18 PER 1000 Nos con688.ia.wb@gembuyer.in 180
6 M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable cross sectional area 300 sqmm 3.5 core. M&L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 300 sqmm 3.5 core. 630 RM con688.ia.wb@gembuyer.in 180
7 All as per Item Sl No. 6 above but of size 240 Sqmm 3.5 Core. All as per Item Sl No. 6 above but of size 240 Sqmm 3.5 Core. 1290 RM con688.ia.wb@gembuyer.in 180
8 All as per Item Sl No. 6 above but of size 185 Sqmm 3.5 Core. All as per Item Sl No. 6 above but of size 185 Sqmm 3.5 Core. 450 RM con688.ia.wb@gembuyer.in 180
9 All as per Item Sl No. 6 above but of size 25 Sqmm 3.5 Core. All as per Item Sl No. 6 above but of size 25 Sqmm 3.5 Core. 200 RM con688.ia.wb@gembuyer.in 180
10 S and F 50 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm fixed complete to walls ceilings or in floors etc. complete all as specified and directed . S & F 50 mm High density polyethylene pipe (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. complete all as specified and directed . 20 RM con688.ia.wb@gembuyer.in 180
11 S and F Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing, fixing to Pole with Mild Steel Clamps Nuts Bolts etc. S&F Galvanised Iron Pipe 50mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. 24 RM con688.ia.wb@gembuyer.in 180
12 S and F Galvanised Iron Pipe 100mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. S&F Galvanised Iron Pipe 100mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. 24 RM con688.ia.wb@gembuyer.in 180
13 S and F Galvanised Iron Pipe 150mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps S&F Galvanised Iron Pipe 150mm Bore (dia) Light Grade for protection of UG Cable, laid in Floors/ Road Crossing, fixing to Pole with Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed. 12 RM con688.ia.wb@gembuyer.in 180
14 Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10. mtr in a Single Length Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore (dia), under Road /Foot Path, not exc. 10.00 mtr in a Single Length, complete all as specified and as directed. Note. Pipe to be measured separately. 36 RM con688.ia.wb@gembuyer.in 180
15 M and L Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC XLPE etc. M&L Straight Through Cable Joint Kit including Jointing Materials for making Joints of UG Electric Cable 1100 Volt Grade Heavy Duty with PVC/XLPE insulated Aluminium Stranded Conductor,Nominal Cross Sectional area exc. 240 to 300 Sqmm , 3.5Core and Testing complete all as specified and as directed 2 Each Joint con688.ia.wb@gembuyer.in 180
16 S and F HDPE DWC Double Walled Corrugated of Diameter 100 mm including disconnection and connection of cable near panel OH for pipe fixing including joints complete all as directed. S & F HDPE DWC (Double Walled Corrugated) of Diameter 100 mm including disconnection and connection of cable near panel/OH for pipe fixing including joints complete all as directed. 12 RM con688.ia.wb@gembuyer.in 180
17 Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated Supply, commissioning and testing Outdoor type LT Distribution Panel, Double door type, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP 54 protection, installed on concrete base made of PCC 1.3.6 C1 using 20mm graded aggregate ,including self locking arragement 5 Each con688.ia.wb@gembuyer.in 180
18 Dismantling of ACSR or AAC conductors complete all as specified and as directed. Dismantling of ACSR or AAC conductors,complete all as specified and as directed. 15 Qtl con688.ia.wb@gembuyer.in 180
19 Dismantling of cross arms of MS channel or angle iron sections etc complete and setting aside all as specified Dismantling of cross arms of MS channel or angle iron sections etc complete and setting aside all as specified 3 Qtl con688.ia.wb@gembuyer.in 180
20 Dismantling Insulators like Pin type disc type for HT from existing Electric Poles of any description and any size complete all as specified and as directed. Dismantling Insulators like Pin type, disc type for HT from existing Electric Poles of any description and any size, complete all as specified and as directed. 227 Each con688.ia.wb@gembuyer.in 180
21 Dismantling of unserviceable service wire cable of any size type complete complete all as specified and as directed. Dismantling of unserviceable service wire/cable of any size/type complete complete all as specified and as directed. 250 RM con688.ia.wb@gembuyer.in 180
22 Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit etc. Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized strip of 32 mm x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1.3.6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed. 10 Each set con688.ia.wb@gembuyer.in 180